BGX BiostreamTM

Process up to

280

SCFM per unit*

Process up to

450

NCMH per unit*

*Up to 450 NCMH per unit

*Up to 280 SCFM per unit

Discover the BGX Biostream™ Technologies

Process

0

SCFM

Up to

0

SCFM per unit

Over

0%

availability

*Up to 450 NCMH per unit

Xebec PSA – How the BGX Biostream™ Gets Its High Reliability

Xebec’s PSA unit consists of Nine Identical Beds filled with High-Efficiency adsorbents. These beds are connected via a single proprietary rotary valve controlling all steps in the adsorption process.

The Adsorption Process

  • One-step fast cycle PSA technology separates H2O/CO2/N2/O2/NH3/H2S from landfill/WWTP/digester gas to produce RNG/Biomethane product
  • Partial N2/O2 removal
  • Superior performance - up to 98.5% methane recovery
BGX Biostream PSA Technology

Continue producing upgraded biogas even when impurity levels change.
Our fast-cycle rotary valve automatically adjusts to keep your BGX BiostreamTM always running to maximize profitability.

process4-en

Low Power Consumption

Xebec’s low-pressure PSA operation and advanced Control system make for the lowest power consumptions in biogas upgrading.

Ampoule - Low power cumsumption

BGX Biostream™ | Technical Specifications

BGX Biostream™

BGX Biostream sample machine

BGX Biostream+™

BGX Biostream sample machine

55-140

SCFM PROCESSING
CAPACITY

30-55kWh

POWER
CONSUMPTION

40-100%

TURN
DOWN

*90-225 NCMH

55-280

SCFM PROCESSING
CAPACITY

40-110kWh

POWER
CONSUMPTION

20-100%

TURN
DOWN

*90-450 NCMH

97+%

BIOGAS
PURITY

98.5+%

METHANE
RECOVERY

20 years

LIFETIME
RELIABILITY

10+ years

PSA ADSORBENT
LIFETIME

<85[email protected]

NOISE
LEVEL

Other Features Included:

  • Fully Automated Control System
  • Local Area Network (eWON-Tablet Access to control system)
  • Remote Access to SCADA
  • Automatic Ambiant Temperature Control Inside Container
  • Cold Climate Package (-40°C/°F)
  • Gas Analyzer for Process Control: CH4, CO2, O2, H2S, and H2O (Product and inlet gas)
  • Gas Flow Meters (Inlet gas, RNG and tail gas)
  • Instrument Air
  • O2 Generator** included for H2S Removal Unit
  • H2S Removal Unit***
  • VFD for all Rotary Equipment
  • Piping and electrical wiring inside the container
  • Supervision of installation****
  • Commissioning, start-up, testing, and training****

* RNG Booster compressor can be offered up to 4000 PSIG

** Additional O2 Generator can be added upon client request

*** Lead-lag H2S towers can be offered as an option

**** Multiple units operating in parallel is possible